|DGCA Portal
Om Agro Drones Logo
OM AGRO DRONESDGCA
FACTORY VERIFICATION PROTOCOLS

Quality Assurance & Multi-Stage Stress Testing

Before any Om Agro drone is packed into its transit case and awarded a stamped UIN plate, it must pass 4 exhaustive statutory stress tests conducted at our Waluj aerospace quality bay.

Protocol #1

Electrical Stress & Thermal Imaging

Testing Scope & Parameter:

PDB, ESCs and motor coil temperature under continuous 100% full-throttle test bench simulation.

Strict Pass Criteria:

Operating temperature strictly < 65°C after 15 minutes continuous peak discharge. Zero hotspots or solder joint softening.

Testing Instrumentation:

FLIR E8-XT Calibrated Infrared Thermal Camera & 200A Programmable Electronic Load.

Protocol #2

Propeller Dynamic Balance & Vibration Analysis

Testing Scope & Parameter:

Tri-axial accelerometer vibration analysis across X, Y, and Z axes at 1,800 to 2,400 RPM motor speeds.

Strict Pass Criteria:

Total composite vibration amplitude strictly < 0.2g across all axes. Zero structural resonance across carbon booms.

Testing Instrumentation:

Tri-Axial High-Frequency Piezoelectric Accelerometers & Digital Dynamic Balancer.

Protocol #3

Fluid Pressure Leakage & Pump Flow Test

Testing Scope & Parameter:

Pressurized tank, chemical-resistant hoses, inline filters, and atomizing spray nozzle manifold integrity.

Strict Pass Criteria:

Zero fluid leakage and zero pressure drop over 15 minutes continuous testing at 3.0 bar hydrostatic pressure.

Testing Instrumentation:

Digital Hydrostatic Test Rig with 0.01-bar precision transducer and micron flow sensor.

Protocol #4

GPS, Compass Degaussing & RTK Lock Verification

Testing Scope & Parameter:

Cold-start satellite acquisition speed, magnetic compass interference index, and centimeter RTK differential lock.

Strict Pass Criteria:

Centimeter RTK fix achieved in < 30 seconds. Horizontal Dilution of Precision (HDOP) strictly < 1.0 with 24+ satellites tracked.

Testing Instrumentation:

Multi-GNSS RF Signal Simulator & Helmholtz Degaussing Electromagnetic Chamber.

Pre-Delivery Quality Inspection Certificate (PDIC)

Every delivered drone includes a serialized Pre-Delivery Inspection Certificate physically signed by Chief Technical Officer Ganesh Janardhan Argade and Founder Ashok Janardhan Argade. The certificate details motor vibration harmonics, thermal IR scan graphs, calibrated nozzle flow rates, and the 100% verified DGCA UIN plate registration number.